Autor: |
Zanelli, Claudio, Giridhar, Dushyanth, Keswani, Manish, Okada, Nagaya, Hsu, Jyhwei, Yam, Petrie |
Jazyk: |
angličtina |
Rok vydání: |
2016 |
Druh dokumentu: |
Článek |
ISSN: |
0277-786X |
DOI: |
10.1117/12.2243124 |
Popis: |
Wet photomask cleaning relies on megasonic agitation to enhance the process, but there are many challenges to reliably maximize particle removal efficiency (PRE) and minimize damage. With the shift to pellicle-free EUV masks, photomask processes are more vulnerable to contamination, increasing the urgency to improve the cleaning process. This difficulty is largely due to the unavailability of appropriate measurement of the acoustic field. Typically all that is known about the acoustic output is the driving frequency and the electric power delivered to a transducer, both global parameters that tell little about the field distribution over the substrate, the actual amplitude of the sound at the substrate, or the levels of cavitation (stable and transient) present at the substrate. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). |
Databáze: |
Networked Digital Library of Theses & Dissertations |