Autor: |
Abdelrahim, M.E.A., Assi, Khaled H., Chrystyn, Henry |
Jazyk: |
angličtina |
Rok vydání: |
2013 |
Předmět: |
|
Druh dokumentu: |
Článek |
DOI: |
10.3109/10837450.2011.620970 |
Popis: |
Previously, dose emission below 30 L min(-1) through DPI has not been routinely determined. However, during routine use some patients do not achieve 30 L min(-1) inhalation flows. Hence, the aim of the present study was to determine dose emission characteristics for low inhalation flows from terbutaline sulphate Turbuhaler. Total emitted dose (TED), fine particle dose (FPD) and mass median aerodynamic diameter (MMAD) of terbutaline sulphate Turbuhaler were determined using inhalation flows of 10-60 L min(-1) and inhaled volume of 4 L. TED and FPD increase significantly with the increase of inhalation flows (p |
Databáze: |
Networked Digital Library of Theses & Dissertations |
Externí odkaz: |
|