Anterior transarticular screw fixation for atlantoaxial arthrodesis: A report of two cases

Autor: C S Carrier, A A Sama, F P Girardi, D R Lebl
Jazyk: angličtina
Rok vydání: 2013
Předmět:
Zdroj: Journal of Craniovertebral Junction and Spine, Vol 4, Iss 2, Pp 85-89 (2013)
Druh dokumentu: article
ISSN: 0974-8237
DOI: 10.4103/0974-8237.128540
Popis: The sequelae of atlantoaxial instability (AAI) range from axial neck pain to life-threatening neurologic injury. Instrumentation and fusion of the C1-2 joint is often indicated in the setting of clinical or biomechanical instability. This is the first clinical report of anterior Smith-Robinson C1-2 transarticular screw (TAS) fixation for AAI. The first patient presented with ischemic brain tissue secondary to post-traumatic C1-2 segment instability from a MVC 7 years prior to presentation. The second patient presented with a 3 year history of persistent right-sided neck and upper scalp pain. Both were treated with transarticular C1-2 fusion through decortication of the atlantoaxial facet joints and TAS fixation via the anterior Smith-Robinson approach. At 16 months follow-up, the first patient maintained painless range of motion of the cervical spine and denied sensorimotor deficits. The second patient reported 90% improvement in her pre-operative symptoms of neck pain and paresthesia. Anterior Smith-Robinson C1-2 TAS fixation provides a useful alternative to the posterior Goel and Magerl techniques for C1-2 stabilization and fusion.
Databáze: Directory of Open Access Journals