Popis: |
Abstract Background Fibrin glue is an absorbable blood-derived product, a biological tissue adhesive which imitates the final stages of the coagulation cascade, it produces a firm clot, forming a seal along the whole length of the wound, the resultant fibrin clot degrades physiologically into granulation tissue 2 weeks after the application. Biological glue has been used extensively in many forms of surgical procedures. Its use in eye surgery has grown lately as we have evidence that showed it was effective in securing conjunctival grafts in pterygium surgery, in securing wounds after glaucoma surgery and more importantly in 20G and 23G vitrectomy. Purpose The aim of this study is to present our experience in the use of fibrin glue in vitreoretinal surgery. Material and methods We included 281 eyes of 221 patients who underwent vitreoretinal surgery during the period of May 2009 to July 2012, the preoperative diagnoses were as following: proliferative diabetic retinopathy, rhegmatogenous retinal detachment, macular hole, epiretinal membrane, luxation of cataratous nucleous and cortex, intraocular lens luxation, penetrating trauma, silicone extraction, phaco + IOL + vitrectomy + Ahmed valve implant, vitreous biopsy and optic nerve pit associated to macular detachment. The procedures were performed with Alcon Accurus Surgical System 20-gauge, 23-gauge or a combination of both. We used fibrin glue in all of the 20-gauge sclerotomies and leaking 23-gauge sclerotomies, scleral wound for IOL extraction, conjunctival peritomy for buckle implantation, conjunctiva in Ahmed valve implant, corneal graft in corneal perforation in trauma and leaking corneal wounds for phacoemulsification, in an optic pit, and in subretinal space in a giant retinal tear. Results We did not use any suture in any of the patients throughout the different procedures, there was no leakage in any wounds in the postoperative period, we found no inflammatory reaction, infection, and whenever we had excess amount, it was trimmed. Two patients presented a small dehiscence of the wound that was corrected in-office with a small amount of fibrin glue in the post-operative period. Conclusions Fibrin glue reduces surgical time, it is a good sealant, safe, with minimal allergic or toxic reactions and inflammation, minimizes bleeding, easy to undo and that eventually degrades. This small series shows that fibrin glue is a viable alternative for tissue coaptation in vitreoretinal surgery. However, further studies are required before fibrin glue takes the place of sutures. |