Value of carotid corrected flow time or changes value of FTc could be more useful in predicting fluid responsiveness in patients undergoing robot-assisted gynecologic surgery: a prospective observational study

Autor: Xixi Tang, Jingqiu Liang, Dongling Tan, Qi Chen, Chengfu Zhou, Tingjun Yang, Hongliang Liu
Jazyk: angličtina
Rok vydání: 2024
Předmět:
Zdroj: Frontiers in Medicine, Vol 11 (2024)
Druh dokumentu: article
ISSN: 2296-858X
DOI: 10.3389/fmed.2024.1387433
Popis: BackgroundThe aim of this study was to evaluate the ability of point-of-care Doppler ultrasound measurements of carotid corrected flow time and its changes induced by volume expansion to predict fluid responsiveness in patients undergoing robot-assisted gynecological surgery.MethodsIn this prospective study, carotid corrected flow time was measured using Doppler images of the common carotid artery before and after volume expansion. The stroke volume index at each time point was recorded using noninvasive cardiac output monitoring with MostCare. Of the 52 patients enrolled, 26 responded.ResultsThe areas under the receiver operating characteristic curves of the carotid corrected flow time and changes in carotid corrected flow time induced by volume expansion were 0.82 and 0.67, respectively. Their optimal cut-off values were 357 and 19.5 ms, respectively.ConclusionCarotid corrected flow time was superior to changes in carotid corrected flow time induced by volume expansion for predicting fluid responsiveness in this population.
Databáze: Directory of Open Access Journals