Popis: |
Abstract Background Several machine learning (ML) classifiers for thyroid nodule diagnosis have been compared in terms of their accuracy, sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), and area under the receiver operating curve (AUC). A total of 525 patients with thyroid nodules (malignant, n = 228; benign, n = 297) underwent conventional ultrasonography, strain elastography, and contrast-enhanced ultrasound. Six algorithms were compared: support vector machine (SVM), linear discriminant analysis (LDA), random forest (RF), logistic regression (LG), GlmNet, and K-nearest neighbors (K-NN). The diagnostic performances of the 13 suspicious sonographic features for discriminating benign and malignant thyroid nodules were assessed using different ML algorithms. To compare these algorithms, a 10-fold cross-validation paired t-test was applied to the algorithm performance differences. Results The logistic regression algorithm had better diagnostic performance than the other ML algorithms. However, it was only slightly higher than those of GlmNet, LDA, and RF. The accuracy, sensitivity, specificity, NPV, PPV, and AUC obtained by running logistic regression were 86.48%, 83.33%, 88.89%, 87.42%, 85.20%, and 92.84%, respectively. Conclusions The experimental results indicate that GlmNet, SVM, LDA, LG, K-NN, and RF exhibit slight differences in classification performance. |