Abstract Background Our study aimed to compare the time consumption and success rate between CTA- and CTP- based assessment strategy, and to clarify the risk factors associated with the CTP scan failure. Methods Clinical and radiological data of 437 consecutive AIS patients who underwent multiphase CTA or CTP for pre-treatment evaluation were retrospectively enrolled (CTA group, n = 302; CTP group, n = 135). Time consumption and success rate of CTA- and CTP- based assessment strategy were compared using Mann–Whitney U test and Chi-Squared Test. Univariate analysis and receiver operating curve analysis were used to clarify the risk factors, and their performance in predicting the CTP scan failure. Results Time consumption of CTP scan and reconstruction was significantly longer than that of CTA [775 s vs 263.5 s, P |