Autor: |
Irati Sanchez Duo, Jose Luis Lanzagorta, Iratxe Aizpurua Maestre, Lander Galdos |
Jazyk: |
angličtina |
Rok vydání: |
2024 |
Předmět: |
|
Zdroj: |
Sensors, Vol 24, Iss 19, p 6360 (2024) |
Druh dokumentu: |
article |
ISSN: |
1424-8220 |
DOI: |
10.3390/s24196360 |
Popis: |
Time-of-Flight Diffraction (TOFD) is a method of ultrasonic testing (UT) that is widely established as a non-destructive technique (NDT) mainly used for the inspection of welds. In contrast to other established UT techniques, TOFD is capable of identifying discontinuities regardless of their orientation. This paper proposes a redesign of the typical TOFD transducers, featuring an innovative curved sole aimed at enhancing their defect detection capabilities. This design is particularly beneficial for thick-walled samples, as it allows for deeper inspections without compromising the resolution near the surface area. During this research, an evaluation consisting in simulations of the ultrasonic beam distribution and experimental tests on a component with artificially manufactured defects at varying depths has been performed to validate the new design. The results demonstrate a 30 to 50% higher beam distribution area as well as an improvement in the signal-to-noise ratio (SNR) resulting in a 24% enhancement in the capability of defect detection compared to the traditional approach. |
Databáze: |
Directory of Open Access Journals |
Externí odkaz: |
|