Airway leakage due to malpositioning of esophageal temperature probe during robot-assisted radical prostatectomy: a case report
Autor: | Jong Min Lee, Chang Mook Lim, Jae Hoon Jung, Seok Jin Lee, Hong Seuk Yang, Chang Yeong Jeong, Dong Ho Park |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2024 |
Předmět: | |
Zdroj: | Journal of International Medical Research, Vol 52 (2024) |
Druh dokumentu: | article |
ISSN: | 1473-2300 03000605 |
DOI: | 10.1177/03000605231224231 |
Popis: | Measuring patients’ core body temperature during surgery is essential and commonly performed with an esophageal temperature probe. The probe must be placed in the lower third of the esophagus for accurate measurement. In this case report, we describe our experience of discovering an inadvertently malpositioned esophageal temperature probe in the right inferior lobar bronchus, which led to ventilation-related problems in a patient undergoing prostate surgery. |