Autor: |
Muhammad Hasib Khalil, MBBS, Mobeen Haider, MBBS, Sanjay Mehta, MD |
Jazyk: |
angličtina |
Rok vydání: |
2024 |
Předmět: |
|
Zdroj: |
Radiology Case Reports, Vol 19, Iss 4, Pp 1386-1390 (2024) |
Druh dokumentu: |
article |
ISSN: |
1930-0433 |
DOI: |
10.1016/j.radcr.2023.12.047 |
Popis: |
Patent foramen ovale (PFO) is a flaplike opening in the fossa ovalis; between the septum primum and secundum. It is highly prevalent with approximately 25% of the population having a PFO. It is usually asymptomatic but can rarely cause paradoxical embolism leading to stroke and/or significant right to left shunting causing hypoxia. The complications of PFO closure with a percutaneous device include embolization, cardiac perforation, and thrombosis. These are all early complications. We describe the case of a patient with a history of PFO closure who had device thrombosis 3 years after implantation. Management includes anticoagulation with warfarin. Repeat cardiac imaging to document the resolution of thrombosis is recommended. |
Databáze: |
Directory of Open Access Journals |
Externí odkaz: |
|