Early Prediction of Non Invasive Ventilation Failure and Mortality in Chronic Obstructive Pulmonary Disease Patients using HACOR Score: A Cross-sectional Study

Autor: DV Pratapa Reddy, V Vijaya Kumari, K Kanaka Lakshmi, R Sunil Kumar, BMS Patrudu, S Praveena, A Vivek, P Siva Subramanian
Jazyk: angličtina
Rok vydání: 2024
Předmět:
Zdroj: Journal of Clinical and Diagnostic Research, Vol 18, Iss 12, Pp 05-09 (2024)
Druh dokumentu: article
ISSN: 2249-782X
0973-709X
DOI: 10.7860/JCDR/2024/73571.20404
Popis: Introduction: Non Invasive Ventilation (NIV) is an effective ventilatory measure in the exacerbation of Chronic Obstructive Pulmonary Disease (COPD). However, the response among some patients is not favourable, leading to a requirement for invasive ventilation. This not only increases hospital stays but is also reported to elevate mortality rates. Therefore, there is a need for a scoring system that predicts NIV failures. The Heart rate, Acidosis, Consciousness, Oxygenation and Respiratory rate (HACOR) score is a promising tool that has demonstrated excellent predictive power in detecting early NIV failure. Aim: To predict NIV failure based on the HACOR score at two hours after the initiation of NIV in patients admitted for acute exacerbation of COPD with type 2 respiratory failure. Materials and Methods: The present hospital-based cross-sectional study was conducted in the Department of Pulmonary Medicine, Government Hospital for Chest and Communicable Diseases, Andhra Medical College, Visakhapatnam, Andhra Pradesh, India, from November 2023 to April 2024. A total of 70 patients admitted with acute exacerbation of COPD and type 2 respiratory failure were included. All five variables of the HACOR score were measured two hours after the initiation of NIV to predict early NIV failure. These variables include heart rate, arterial blood pH, Glasgow Coma Scale (GCS) score (consciousness), oxygenation and respiratory rate. After the initiation of NIV, the HACOR score was evaluated at various intervals. The diagnostic accuracy of the HACOR score in predicting NIV failure was recorded, which was the main outcome of the study. Receiver Operating Characteristic (ROC) curve and Youden index were applied. The dependent variables were analysed using the Youden index to obtain the best cut-off value of the HACOR score. Results: Out of 70 patients, 66 (94.3%) were males and 4 (5.7%) were females, with a mean±Standard Deviation (SD) age of 68.5±6.1 years. The study reported a 27.1% (19 patients) NIV failure rate based on the HACOR score measured after two hours of NIV. The total study population was divided into two groups based on the measured HACOR score cut-off value of 5. A total of 33 patients had a score ≥5, while 37 patients had a score
Databáze: Directory of Open Access Journals