Autor: |
Sumanta Pal, Kiran Kumar Mukhopadhyay, Anant Kumar Garg, Sanjay Kumar, Pradip Mukherjee |
Jazyk: |
angličtina |
Rok vydání: |
2019 |
Předmět: |
|
Zdroj: |
Journal of Orthopedics, Traumatology and Rehabilitation, Vol 11, Iss 1, Pp 44-48 (2019) |
Druh dokumentu: |
article |
ISSN: |
0975-7341 |
DOI: |
10.4103/jotr.jotr_13_19 |
Popis: |
Study Design: Open level experimental design. Purpose: Ceramics are effective, safe, and good alternatives of iliac crest autograft for spinal fusion. There were not enough study available to compare among ceramics for fusion in spinal surgery. Our aim was comparative assessment of posterolateral spinal arthrodesis radiologically and clinically in dorsolumbar spine trauma using hydroxyapatite (HA), tricalcium phosphate (TCP), and 60% HA + 40% TCP. Overview of Literature: Surgical management of thoracolumbar spine injury has encouraged early rehabilitation and avoided adverse effects of prolonged recumbency. Instrumentation enhanced spinal fusion which was the main technique of spinal stabilization. Although iliac crest autograft is the gold standard for spinal fusion,the procedure is not devoid of major and minor complications. A variety of ceramics are available as good alternatives for spinal arthrodesis. There are not any studies in the literature comparing spinal fusion rate among commonly used ceramics. Materials and Methods: Patients having Thoraco Lumbar Injury Classification and Severity score ≥4 underwent pedicle screw fixation and decompression (if required). We applied chips of HA, TCP, or 60% HA + 40% TCP for fusion. At 12-month follow-up, computed tomography scan of involved spine was done to assess posterolateral fusion by Lenke classification. Clinical follow-up was done evaluating pain status (visual analog scale). Mean follow-up duration was 27.8 months. Radiological and clinical parameters were compared among three groups. Results: A total of 45 patients (16 received HA, 15 received TCP, and 14 received [60%HA + 40%TCP]) were analyzed. About 28.88% of total patients had Lenke Grade A fusion and 51.11% had Grade B, but no statistically significant difference (P = 0.09) among three groups. Although reduction of pain score occurred individually in all three groups,no significant difference (P = 0.3)was noted among three groups. Conclusions: There was no statistically significant difference in fusion rate and change in pain perception with applied ceramics (HA/TCP/[60%HA + 40%TCP]). |
Databáze: |
Directory of Open Access Journals |
Externí odkaz: |
|