Method to Reduce the False-Positive Rate of Loss of Resistance in the Cervical Epidural Region

Autor: Young Uk Kim, Doohwan Kim, Jun Young Park, Jae-Hyung Choi, Ji Hyun Kim, Heon-Yong Bae, Eun-Young Joo, Jeong Hun Suh
Jazyk: angličtina
Rok vydání: 2016
Předmět:
Zdroj: Pain Research and Management, Vol 2016 (2016)
Druh dokumentu: article
ISSN: 1203-6765
1918-1523
DOI: 10.1155/2016/9894054
Popis: Background. The cervical epidural space can be detected by the loss of resistance (LOR) technique which is commonly performed using air. However, this technique using air has been associated with a high false-positive LOR rate during cervical interlaminar epidural steroid injections (CIESIs). Objective. We investigated whether the detection of LOR with contrast medium might reduce the false-positive LOR rate on the first attempt. Methods. We obtained data retrospectively. A total of 79 patients were divided into two groups according to the LOR technique. Groups 1 and 2 patients underwent CIESI with the LOR technique using air or contrast medium. During the procedure, the injection technique (median or paramedian approach), final depth, LOR technique (air or contrast), total number of LOR attempts, and any side effects were recorded. Results. The mean values for the total number of LOR attempts were 1.38 ± 0.65 (Group 1) and 1.07 ± 0.25 (Group 2). The false-positive rate on the first attempt was 29.4% and 6.6% in Groups 1 and 2, respectively (P=0.012). Conclusions. The use of contrast medium for LOR technique is associated with a lower rate of false-positivity compared with the use of air.
Databáze: Directory of Open Access Journals