Autor: |
Chromíková Jitka, Heviánková Silvie, Kyncl Miroslav, Korabík Michal, Marschalko Marian |
Jazyk: |
angličtina |
Rok vydání: |
2017 |
Předmět: |
|
Zdroj: |
GeoScience Engineering, Vol 63, Iss 4, Pp 13-19 (2017) |
Druh dokumentu: |
article |
ISSN: |
1802-5420 |
DOI: |
10.1515/gse-2017-0018 |
Popis: |
The purpose of this study is to evaluate the potential for infiltration in a study area – Rožnov pod Radhoštěm, the Czech Republic. The results are important for the future design of an artificial recharge structure as a method to store water underground in times of water surplus. A total of six measurements of infiltration were made using a double ring infiltrometer on selected prospective sites for the future application of artificial recharge. The results of infiltration tests were analysed based on the Philip’s model. The steady soil infiltration rates ranged from 28 cm∙h−1 to 70.38 cm∙h−1and the cumulative soil infiltration ranged from 58 cm to 68 cm. |
Databáze: |
Directory of Open Access Journals |
Externí odkaz: |
|