Validated TLC-densitometric analysis for determination of carotenoids in fancy carp (Cyprinus carpio ) serum and the application for pharmacokinetic parameter assessment

Autor: Bundit Yuangsoi, Orapint Jintasataporn, Nontavit Areechon, Prathak Tabthipwon
Jazyk: angličtina
Rok vydání: 2008
Předmět:
Zdroj: Songklanakarin Journal of Science and Technology (SJST), Vol 30, Iss 6, Pp 693-700 (2008)
Druh dokumentu: article
ISSN: 0125-3395
Popis: A densitometric Thin-layer Chromatographic (TLC) method of carotenoids such as astaxanthin, lutein, and B-carotene have been established and validated for quantitative determination of carotenoids in fancy carp serum. This study can be used in the evaluation of pharmacokinetic parameters of carotenoids in fancy carp serum. Analyses of carotenoids were performed on TLC glass plates pre-coated with silica gel 60 as the stationary phase. Linear ascending development was carried out in a twin trough glass chamber saturated with mobile phase consisting of petroleum ether-diethyl ether-acetone(75:15:10, v/v/v) at a temperature of 25±2oC. TLC scanner was used for spectrodensitometric scanning and analysis inabsorbance mode at 450 nm. The system was found to give compact spots for astaxanthin, lutein, and b-carotene (Rf values of 0.21, 0.17 and 0.97, respectively). The method was validated for linearity, precision, accuracy, LOD, LOQ and HORRAT value. The linear regression analysis data of astaxanthin, lutein, and b-carotene for the calibration plots showed a good linear relationship with r2 = 0.999, 0.998 and 0.998, respectively, in a concentration range of 0.01-6.50 ug/spot with respect to the peak area. Precision (% RSDr) of astaxanthin, lutein, and b-carotene was 2.93, 3.34, and 2.61, respectively. The limit of detection (LOD) was 0.011, 0.023 and 0.026 μg/spot, respectively. The additionally limit of quantization (LOQ) was 0.036, 0.075 and 0.085 μg/spot, respectively. The percent recoveries of astaxanthin, lutein, and b-carotene spiked to sample blank showed an average of percent recoveries for astaxanthin (0.3-2.0 mg/ml) of 91.70%, for lutein(0.2-3.0 mg/ul) of 90.47%, and for b-carotene (0.1-1.0 mg/ul) of 102.25%. In all carotenoids, the HORRAT values were below the critical value. Therefore, this method enables simple, rapid, economical and precise quantitative determination of carotenoids in fancy carp serum for evaluated pharmacokinetic parameters. It is possible to use the established method for the routine analysis of carotenoids in serum.
Databáze: Directory of Open Access Journals