Resultados preliminares da artroplastia do quadril metal-metal de superfície: análise dos primeiros 40 casos com seguimento médio de 3 anos Preliminary outcomes of hip metal-on-metal resurfacing arthroplasty: an analysis of the first 40 cases with mean follow-up time of 3 years
Autor: | Mauricio de Moraes, Rubens Rodrigues, Robert Barr, Nelson Keiske Ono, Edson Noboru Fujiki, Carlo Milani |
---|---|
Jazyk: | English<br />Portuguese |
Rok vydání: | 2008 |
Předmět: | |
Zdroj: | Acta Ortopédica Brasileira, Vol 16, Iss 1, Pp 19-22 (2008) |
Druh dokumentu: | article |
ISSN: | 1413-7852 1809-4406 |
DOI: | 10.1590/S1413-78522008000100003 |
Popis: | Quarenta quadris (39 pacientes) foram submetidos à artroplastia total metal-metal de superficie "resurfacing" entre 2002 e 2005. Todos foram estudados e analisados clinicamente e radiograficamente. Foram utilizados critérios clínicos, no pré e pós-operatório, pela avaliação de D'Aubigné e Postel. Radiograficamente, as áreas de radiolucência ao redor do acetábulo foram classificadas de acordo com DeLee e Charnley e, no fêmur nas zonas descritas por Amstutz et al. A idade média foi de 54,40 anos. O seguimento mínimo foi de 14 meses e o máximo de 51(média de 37,36 meses). 94,44% dos resultados clínicos foram satisfatórios no pós-operatório. Ocorreram 2 casos de soltura asséptica. Não houve fratura do fêmur durante o seguimento. Os autores consideraram esta opção técnica e de implante satisfatória e, com bons resultados no seguimento médio de 3 anos.Forty hips (39 patients) were submitted to metal-on-metal hip replacement (resurfacing) between 2002 and 2005. Evaluation was provided by clinical examination and X-ray tests. The authors performed clinical evaluations before and after surgery. The specific criterion applied was the D'Aubigné and Postel's classification. X-ray images showed radiolucent lines around the acetabular component on the zones described by DeLee and Charnley and around the femoral component on the zones described by Amstutz et al. The mean age was 54.40 years. The minimum follow-up period was 14 months (range:12 to 51 months). The outcomes of 94.44% of the patients in the study were postoperatively rated as satisfactory. There were 2 cases of aseptic loose and no neck-femoral fractures during the follow-up period. The authors concluded that this technique and implant alternative is satisfactory, with good early outcomes in a mean follow-up time of three years. |
Databáze: | Directory of Open Access Journals |
Externí odkaz: |