Transient fixation of L4 vertebra preserves lumbar motion and function in Lenke Type 5C and 6C scoliosis

Autor: Jae-Ho Yang, Jae-Won Shin, Sub-Ri Park, Sun-Kyu Kim, Sang-Jun Park, Ji-Hwan Min, Byoung-Ho Lee, Kyung-Soo Suk, Jin-Oh Park, Seong-Hwan Moon, Hwan-Mo Lee, Hak-Sun Kim
Jazyk: angličtina
Rok vydání: 2021
Předmět:
Zdroj: Scientific Reports, Vol 11, Iss 1, Pp 1-9 (2021)
Druh dokumentu: article
ISSN: 2045-2322
DOI: 10.1038/s41598-021-89674-7
Popis: Abstract This study investigated the efficacy of a novel surgical method that relies on the transient fixation of L4 in Lenke Type 5C and 6C adolescent idiopathic scoliosis. Thirty-six transient surgically treated L4 fixation patients were retrospectively evaluated. The first surgery involved mechanical correction of scoliosis; the lowest instrumented vertebra (LIV) was L4. After an average of 1.3 years (range, 0.3–3.4), the second surgery to remove transient L4 pedicle screws was performed. Radiographic parameters and SRS-22 scores were measured. Cobb’s angle, coronal balance, LIV tilting angle, and LIV coronal disc angle clearly improved after the first surgery (p