Exploring the Hidden Complexity: Entropy Analysis in Pulse Oximetry of Female Athletes

Autor: Ana M. Cabanas, Macarena Fuentes-Guajardo, Nicolas Sáez, Davidson D. Catalán, Patricio O. Collao-Caiconte, Pilar Martín-Escudero
Jazyk: angličtina
Rok vydání: 2024
Předmět:
Zdroj: Biosensors, Vol 14, Iss 1, p 52 (2024)
Druh dokumentu: article
ISSN: 2079-6374
DOI: 10.3390/bios14010052
Popis: This study examines the relationship between physiological complexity, as measured by Approximate Entropy (ApEn) and Sample Entropy (SampEn), and fitness levels in female athletes. Our focus is on their association with maximal oxygen consumption (VO2,max). Our findings reveal a complex relationship between entropy metrics and fitness levels, indicating that higher fitness typically, though not invariably, correlates with greater entropy in physiological time series data; however, this is not consistent for all individuals. For Heart Rate (HR), entropy measures suggest stable patterns across fitness categories, while pulse oximetry (SpO2) data shows greater variability. For instance, the medium fitness group displayed an ApEn(HR) = 0.57±0.13 with a coefficient of variation (CV) of 22.17 and ApEn(SpO2) = 0.96±0.49 with a CV of 46.08%, compared to the excellent fitness group with ApEn(HR) = 0.60±0.09 with a CV of 15.19% and ApEn(SpO2) =0.85±0.42 with a CV of 49.46%, suggesting broader physiological responses among more fit individuals. The larger standard deviations and CVs for SpO2 entropy may indicate the body’s proficient oxygen utilization at higher levels of physical demand. Our findings advocate for combining entropy metrics with wearable sensor technology for improved biomedical analysis and personalized healthcare.
Databáze: Directory of Open Access Journals