Evaluation of a flash glucose monitoring system in nondiabetic dogs with rapidly changing blood glucose concentrations

Autor: Leigh A. Howard, Jonathan A. Lidbury, Nicholas Jeffery, Shannon E. Washburn, Carly A. Patterson
Jazyk: angličtina
Rok vydání: 2021
Předmět:
Zdroj: Journal of Veterinary Internal Medicine, Vol 35, Iss 6, Pp 2628-2635 (2021)
Druh dokumentu: article
ISSN: 1939-1676
0891-6640
DOI: 10.1111/jvim.16273
Popis: Abstract Background A flash glucose monitoring system (FGMS; FreeStyle Libre) is useful for monitoring hypoglycemic dogs with diabetes. Objective To assess the utility of this FGMS in dogs with induced hypoglycemia and rapid fluctuations in blood glucose (BG) concentrations. Animals Twenty‐four apparently healthy research (n = 10) and teaching (n = 14) dogs. Methods Prospective, observational study performed in tandem with a teaching laboratory. Regular insulin was administered to dogs and resulting hypoglycemia was corrected. Before insulin administration and every 10 minutes over a 90‐minute period, serial measurements of interstitial glucose (IG) with FGMS and BG with a portable blood glucose meter (PBGM) and clinical chemistry analyzer concentrations were made. Portable blood glucose meter and FGMS readings were compared to that of the clinical chemistry analyzer. Analytical and clinical accuracy were assessed using ISO 15197:2013 criteria, including Parkes error grid analysis. Results The proportions of readings in the low BG range (BG
Databáze: Directory of Open Access Journals