System Profit Improvement of a Thermal–Wind–CAES Hybrid System Considering Imbalance Cost in the Electricity Market

Autor: Mitul Ranjan Chakraborty, Subhojit Dawn, Pradip Kumar Saha, Jayanta Bhusan Basu, Taha Selim Ustun
Jazyk: angličtina
Rok vydání: 2022
Předmět:
Zdroj: Energies, Vol 15, Iss 24, p 9457 (2022)
Druh dokumentu: article
ISSN: 1996-1073
DOI: 10.3390/en15249457
Popis: Studying a renewable energy integrated power system’s features is essential, especially for deregulated systems. The unpredictability of renewable sources is the main barrier to integrating renewable energy-producing units with the current electrical grid. Due to its unpredictable nature, integrating wind power into an existing power system requires significant consideration. In a deregulated electricity market, this paper examines the implications of wind farm (WF) integration with CAES on electric losses, voltage profile, generation costs, and system economics. Comparative research was done to determine the impact of wind farm integration on regulated and deregulated environments. Four randomly chosen locations in India were chosen for this investigation, together with real-time information on each location’s real wind speed (RWS) and predicted wind speed (PWS). Surplus charge rates and deficit charge rates were created to assess the imbalance cost arising from the discrepancy between predicted and real wind speeds to calculate the system economics. When the effect of imbalance cost is considered, the daily system profit shows a variation of about 1.9% for the locations under study. Customers are always seeking electricity that is dependable, affordable, and efficient due to the reorganization of the power system. As a result, the system security limit could be exceeded or the system might function dangerously. The final section of this paper presents an economic risk analysis using heuristic algorithms such as sequential quadratic programming (SQP), artificial bee colony algorithms (ABC), and moth flame optimization algorithms (MFO). It also discusses how the CAES is used to correct the deviation of WF integration in the real-time electricity market. Economic risk analysis tools include value-at-risk (VaR) and conditional value-at-risk (CVaR). The entire piece of work was validated using a modified IEEE 30-bus test system. This works shows that with a three-fold increase in wind generation, the risk coefficient values improves by 1%.
Databáze: Directory of Open Access Journals
Nepřihlášeným uživatelům se plný text nezobrazuje