Strategic Electrochemical Determination of Nitrate over Polyaniline/Multi-Walled Carbon Nanotubes-Gum Arabic Architecture
Autor: | Samia Abdulhammed Mohamad Kosa, Amna Nisar Khan, Sana Ahmed, Mohammad Aslam, Wafa AbuBaker Bawazir, Abdul Hameed, Muhammad Tahir Soomro |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2022 |
Předmět: | |
Zdroj: | Nanomaterials, Vol 12, Iss 19, p 3542 (2022) |
Druh dokumentu: | article |
ISSN: | 12193542 2079-4991 |
DOI: | 10.3390/nano12193542 |
Popis: | Significant agricultural and industrial activities necessitate the regular monitoring of nitrate (NO3−) ions levels in feed and groundwater. The current comparative study discloses an innovative user-friendly electrochemical approach for the determination of NO3− over polyaniline (PAni)-based modified electrodes. The electrochemical sensors concocted with PAni, multi-walled carbon nanotubes (CNT), and gum arabic (GA). The unique electrode material GA@PAni-CNT was synthesized by facile one-pot catalytic polymerization of aniline (Ani) with FeCl3/H2O2 in the presence of CNT and GA as integral components. As revealed by cyclic voltammetry (CV), the anchoring/retention of NO3− followed by reduction is proposed to occur when a GA@PAni-CNT electrode is immersed in phosphate buffer electrolyte containing NO3− that eventually results in a significantly higher redox activity of the GA@PAni-CNT electrode upon potential scan. The mechanism of NO3− anchoring may be associated with the non-redox transition of leucomeraldine salt (LS) into emeraldine salt (ES) and the generation of nitrite (NO2−) ions. As a result, the oxidation current produced by CV for redox transition of ES ↔ pernigraniline (PN) was ~9 times of that obtained with GA@PAni-CNT electrode and phosphate buffer electrolyte, thus achieving indirect NO3− voltammetric determination of the GA@PAni-CNT electrode. The prepared GA@PAni-CNT electrode displayed a higher charge transfer ability as compared to that of PAni-CNT and PAni electrodes. The optimum square wave voltammetric (SWV) response resulted in two linear concentration ranges of 1–10 (R2 = 0.9995) and 15–50 µM (R2 = 0.9988) with a detection limit of 0.42 µM, which is significantly lower. The GA@PAni-CNT electrode demonstrated the best detection, sensitivity, and performance among the investigated electrodes for indirect voltammetric determination of NO3− that portrayed the possibility of utilizing GA—stabilized PAni and CNT nanocomposite materials in additional electrochemical sensing applications. |
Databáze: | Directory of Open Access Journals |
Externí odkaz: |