Comparison of 18F-DCFPyL and 68Ga-PSMA-11 for 177Lu-PSMA-617 therapy patient selection

Autor: Surekha Yadav, Sarasa T. Kim, Abuzar Moradi Tuchayi, Fei Jiang, Amanda Morley, Rachelle Saelee, Yingbing Wang, Roxanna Juarez, Courtney Lawnh-Heath, Vadim S. Koshkin, Thomas A. Hope
Jazyk: angličtina
Rok vydání: 2024
Předmět:
Zdroj: Frontiers in Oncology, Vol 14 (2024)
Druh dokumentu: article
ISSN: 2234-943X
DOI: 10.3389/fonc.2024.1382582
Popis: Purpose68Ga-PSMA-11 is recommended for the selection of patients for treatment in the package insert for 177Lu-PSMA-617. We aimed to compare imaging properties and post-treatment outcomes from radioligand therapy (RLT) of patients selected with 68Ga-PSMA-11 and 18F-DCFPyL.MethodsWe retrospectively evaluated 80 patients undergoing PSMA RLT, who had pretreatment imaging using either 68Ga-PSMA-11 or 18F-DCFPyL. For both groups, we compared the biodistribution and lesion uptake and the PSA response to treatment.ResultsBoth agents had comparable biodistribution. Patients initially imaged with 18F-DCFPyL had a higher PSA response (66% vs. 42%), and more patients had a PSA50 response (72% vs. 43%) compared to patients imaged with 68Ga-PSMA-11.Conclusion18F-DCFPyL and 68Ga-PSMA-11 had comparable biodistribution and lesion uptake. Patients imaged with 18F-DCFPyL demonstrated clinical benefit to PSMA RLT comparable to those imaged with 68Ga-PSMA-11, and either agent can be used for screening patients.
Databáze: Directory of Open Access Journals