Solving Noise Pollution Issue Using Plenum Window with Perforated Thin Box

Autor: Hsiao Mun Lee, Andi Haris, Kian Meng Lim, Jinlong Xie, Heow Pueh Lee
Jazyk: angličtina
Rok vydání: 2020
Předmět:
Zdroj: Crystals, Vol 10, Iss 7, p 614 (2020)
Druh dokumentu: article
ISSN: 2073-4352
DOI: 10.3390/cryst10070614
Popis: In the present study, a conventional plenum window was incorporated with perforated thin box in order to enhance its performance at frequency range which centralized at 1000 Hz as most of the common noise sources at city nowadays are centralizing around this frequency. The entire studies were conducted in a reverberation room. The effectiveness of jagged flap on mitigating diffracted sound was also studied. Three types of noises were examined in the current study—white noise, traffic noise and construction noises. The experimental results showed that the plenum window with perforated thin box could reduce 8.4 dBA, 8.7 dBA and 6.9 dBA of white, traffic and construction noises, respectively. The jagged flaps did not have significant effect on the plenum window’s noise mitigation performance. When frequencies were ranging from 800 Hz to 1250 Hz, when compared with the case of without perforated thin box, it was found that the perforated thin box had good acoustic performance where it was able to reduce additional 1.6 dBA, 1.6 dBA and 1.2 dBA of white, construction and traffic noises, respectively.
Databáze: Directory of Open Access Journals