Popis: |
Total knee arthroplasty (TKA) is a cornerstone in addressing knee joint disorders, significantly enhancing patients' quality of life. However, despite technological advancements, a comprehensive understanding of the dynamic stresses experienced by knee prostheses during daily activities, particularly under rehabilitation interventions, remains elusive. This study aims to bridge this gap by employing numerical simulations and finite element analysis to elucidate these dynamic stresses and their interaction with rehabilitation protocols.A real-life knee replacement prosthesis model was meticulously constructed through coordinate measuring and 3D scanning, facilitating detailed finite element analysis in ANSYS Workbench version 17.1. Two distinct boundary conditions and loading scenarios were applied, with comparisons made between linear and nonlinear material assumptions. The simulation results using these different boundary condition methods revealed minimal differences. Specifically, at a knee angle of 0°, the relative stress error rate between the two boundary condition types was approximately 1 % (1.11 MPa and 1.099 MPa, respectively). At 15° and 90°, the error rates were 1.9 % and 0.56 %, respectively (10.275 MPa and 10.078 MPa at 15°; 10.275 MPa and 10.078 MPa at 90°). Given these minimal differences, the first type of boundary condition was adopted for the subsequent scenarios to enhance convergence efficiency in the analysis.Moreover, comparative analyses between linear and nonlinear material behaviors demonstrated acceptable agreement, offering insights into potential efficiency gains in simulation methodologies. Building on this foundation, an optimized tibial model was proposed, incorporating geometric alterations to the tray. Quantitative assessments revealed significant reductions, with von Mises stress decreasing by 23.35 % and equivalent strain by 17 % at a knee angle of 140°. Further evaluations at varying angles, including 60°, consistently showed positive influences on stress and strain. These quantitative findings not only contribute valuable insights into the mechanical behavior of knee prostheses but also provide tangible evidence for the efficacy of linear material behavior assumptions. The proposed optimized model exhibits promising potential for enhancing the design and performance of knee prostheses, particularly under critical loading conditions.In conclusion, these results underscore the importance of a nuanced understanding of knee prosthesis behavior during rehabilitation, offering a quantitative foundation for refining existing designs and informing the development of next-generation prostheses. |