Autor: |
Stefan Cichosz, Anna Masek, Katarzyna Dems-Rudnicka |
Jazyk: |
angličtina |
Rok vydání: |
2022 |
Předmět: |
|
Zdroj: |
Scientific Reports, Vol 12, Iss 1, Pp 1-11 (2022) |
Druh dokumentu: |
article |
ISSN: |
2045-2322 |
DOI: |
10.1038/s41598-022-24097-6 |
Popis: |
Abstract The aim of this research was to evaluate the applicability of the attenuated total reflectance Fourier-transform infrared (ATR FT-IR) spectroscopy in the quantitative analysis of the moisture content in cellulose (from 0.5 to 11.0 wt.%). Innovatively, this work describes the variations in both absorbance and wavenumber of 16 absorption bands plotted as a function of cellulose water amount measured with Karl-Fischer titration. Different regression models were investigated (simple linear, semilogarithmic, power) and the adjusted coefficient of determination (R2) was given for each calculation. While model exhibited R2 > 90%, the standard error of calibration (SEC) was presented and an external validation has been performed. Regarding the absorbance-water content relationship, data recorded for sixteen peaks was successfully fitted with linear functions exhibiting R2 > 90%. The highest value of R2 = 98.7% and standard error of prediction SEP = 0.3wt.% have been assigned to the maximum from 3339 to 3327 cm−1 (–OH), proving ATR FT-IR usefulness in quantitative analysis. |
Databáze: |
Directory of Open Access Journals |
Externí odkaz: |
|
Nepřihlášeným uživatelům se plný text nezobrazuje |
K zobrazení výsledku je třeba se přihlásit.
|