Accidentally Missed Guidewire during Insertion of a Dialysis Catheter
Autor: | Gentle Sunder Shrestha, Anand Thakur, Bashu Dev Parajuli, Navindra Raj Bista, Subhash Prasad Acharya |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2016 |
Předmět: | |
Zdroj: | Indian Journal of Vascular and Endovascular Surgery, Vol 3, Iss 4, Pp 136-137 (2016) |
Druh dokumentu: | article |
ISSN: | 0972-0820 2394-0999 |
DOI: | 10.4103/0972-0820.191495 |
Popis: | Missed guidewire is a rare and potentially avoidable complication of central venous cannulation. Unsupervised insertion by trainees, distraction during insertion, and high workload may increase the risk. Simple measures such as holding onto the wire at all times until removal from the vessel, routine use of central venous catheter insertion checklist, and vigilant supervision of the trainees may help prevent missing of the guidewire. |