Real-World Use Of Ultrathin-Strut Biodegradable Polymer–Coated Sirolimus-Eluting Stents In Patients With Coronary Artery Disease: 6-Month Clinical Outcomes

Autor: Ajmera P, Pothineni R, Chawla KK, Mantravadi SS, Jariwala PV, Vijan V
Jazyk: angličtina
Rok vydání: 2019
Předmět:
Zdroj: Vascular Health and Risk Management, Vol Volume 15, Pp 439-447 (2019)
Druh dokumentu: article
ISSN: 1178-2048
Popis: Prakash Ajmera,1 Ramesh Pothineni,2 Kamal Kumar Chawla,1 Sai Sudhakar Mantravadi,3 Pankaj Vinod Jariwala,4 Vinod Vijan,5 Vikrant Vijan5 1Department of Cardiology, Malla Reddy Narayana Multispeciality Hospital, Hyderabad, Telangana 500055, India; 2Department of Cardiology, Ramesh Hospitals, Vijayawada, Andhra Pradesh 520008, India; 3Department of Cardiology, Gleneagles Global Hospital, Hyderabad, Telangana 500004, India; 4Department of Cardiology, Yashoda Hospitals, Somajiguda, Hyderabad, Telangana, 500082, India; 5Department of Cardiology, Vijan Cardiac and Critical Care Centre, Nashik, Maharashtra 422005, IndiaCorrespondence: Prakash AjmeraMalla Reddy Narayana Multispeciality Hospital, 1-1-216 Suraram Crossroads, Jeedimetla, Hyderabad, Telangana 500055, IndiaTel +91 9985401317Email wglprakash@yahoo.comBackground: Although a number of drug-eluting stents have been developed with different design, composition, and polymers, the search for an ideal drug-eluting stent is ongoing. The Tetriflex (Sahajanand Medical Technology, Surat, India) is a newer-generation, ultrathin (60 μm) biodegradable polymer–coated sirolimus-eluting stent (SES) designed with a unique long dual Z-link on a cobalt–chromium alloy. The present registry aimed to evaluate the safety and clinical outcomes of the Tetriflex SES at 6-month post-implantation.Methods: This was an investigator-initiated, retrospective, multicenter, single-arm, observational registry conducted at five tertiary-care centers in India. A total of 1,269 consecutive patients with coronary artery disease who underwent implantation of at least one Tetriflex SES between March 2017 and March 2018 were included. The primary outcome was considered a composite of cardiac death, myocardial infarction and target-lesion revascularization (TLR) at 6-month follow-up. Stent thrombosis was evaluated as a safety outcome at 6-month follow-up.Results: The mean age of patients was 54.99±10.80 years. Among 1,515 lesions treated with 1,682 Tetriflex SES, 58.3% were type C lesions. Six-month follow-up was done for 1,245 of 1,269 (98.1%) patients. At 6 months, composite events had occurred in 31 (2.5%) patients, consisting of ten (0.8%) cardiac deaths, 16 (1.3%) myocardial infarctions, and five (0.4%) TLRs. Stent thrombosis was observed in seven (0.56%) cases at 6 months. A subgroup analysis between diabetic and nondiabetic patients did not reveal any statistically significant difference for clinical outcomes at 6-month follow-up.Conclusion: The results of the current registry outline the safety and effectiveness of the Tetriflex SES in real-world patients, as it displayed favorable clinical outcomes at 6-month follow-up, with low incidence of TLR and stent thrombosis.Keywords: biodegradable polymer, drug-eluting stents, sirolimus, ultrathin strut
Databáze: Directory of Open Access Journals