Autor: |
Adam Sharabi, Eli Abutbul, Eitan Grossbard, Yonatan Martsiano, Aya Berman, Reut Kassif-Lerner, Hila Hakim, Pninit Liber, Anram Zoubi, Galia Barkai, Gad Segal |
Jazyk: |
angličtina |
Rok vydání: |
2023 |
Předmět: |
|
Zdroj: |
Sensors, Vol 23, Iss 20, p 8464 (2023) |
Druh dokumentu: |
article |
ISSN: |
1424-8220 |
DOI: |
10.3390/s23208464 |
Popis: |
Background: The hospital-at-home (HAH) model is a viable alternative for conventional in-hospital stays worldwide. Serum electrolyte abnormalities are common in acute patients, especially in those with many comorbidities. Pathologic changes in cardiac electrophysiology pose a potential risk during HAH stays. Periodical electrocardiogram (ECG) tracing is therefore advised, but few studies have evaluated the accuracy and efficiency of compact, self-activated ECG devices in HAH settings. This study aimed to evaluate the reliability of such a device in comparison with a standard 12-lead ECG. Methods: We prospectively recruited consecutive patients admitted to the Sheba Beyond Virtual Hospital, in the HAH department, during a 3-month duration. Each patient underwent a 12-lead ECG recording using the legacy device and a consecutive recording by a compact six-lead device. Baseline patient characteristics during hospitalization were collected. The level of agreement between devices was measured by Cohen’s kappa coefficient for inter-rater reliability (Ϗ). Results: Fifty patients were included in the study (median age 80 years, IQR 14). In total, 26 (52%) had electrolyte disturbances. Abnormal D-dimer values were observed in 33 (66%) patients, and 12 (24%) patients had elevated troponin values. We found a level of 94.5% raw agreement between devices with regards to nine of the options included in the automatic read-out of the legacy device. The calculated Ϗ was 0.72, classified as a substantial consensus. The rate of raw consensus regarding the ECG intervals’ measurement (PR, RR, and QT) was 78.5%, and the calculated Ϗ was 0.42, corresponding to a moderate level of agreement. Conclusion: This is the first report to our knowledge regarding the feasibility of using a compact, six-lead ECG device in the setting of an HAH to be safe and bearing satisfying agreement level with a legacy, 12-lead ECG device, enabling quick, accessible arrythmia detection in this setting. Our findings bear a promise to the future development of telemedicine-based hospital-at-home methodology. |
Databáze: |
Directory of Open Access Journals |
Externí odkaz: |
|
Nepřihlášeným uživatelům se plný text nezobrazuje |
K zobrazení výsledku je třeba se přihlásit.
|