Point-of-care prognostication in moderate Covid-19: Analytical validation and prognostic accuracy of a soluble urokinase plasminogen activator receptor (suPAR) rapid test.

Autor: Arjun Chandna, Raman Mahajan, Priyanka Gautam, Lazaro Mwandigha, Sabine Dittrich, Vikash Kumar, Jennifer Osborn, Pragya Kumar, Constantinos Koshiaris, George M Varghese, Yoel Lubell, Sakib Burza
Jazyk: angličtina
Rok vydání: 2023
Předmět:
Zdroj: PLOS Global Public Health, Vol 3, Iss 8, p e0001538 (2023)
Druh dokumentu: article
ISSN: 2767-3375
DOI: 10.1371/journal.pgph.0001538
Popis: The soluble urokinase plasminogen activator receptor (suPAR) has been proposed as a biomarker for risk stratification of patients presenting with acute infections. However, most studies evaluating suPAR have used platform-based assays, the accuracy of which may differ from point-of-care tests capable of informing timely triage in settings without established laboratory capacity. Using samples and data collected during a prospective cohort study of 425 patients presenting with moderate Covid-19 to two hospitals in India, we evaluated the analytical performance and prognostic accuracy of a commercially-available rapid diagnostic test (RDT) for suPAR, using an enzyme-linked immunosorbent assay (ELISA) as the reference standard. Our hypothesis was that the suPAR RDT might be useful for triage of patients presenting with moderate Covid-19 irrespective of its analytical performance when compared with the reference test. Although agreement between the two tests was limited (bias = -2.46 ng/mL [95% CI = -2.65 to -2.27 ng/mL]), prognostic accuracy to predict supplemental oxygen requirement was comparable, whether suPAR was used alone (area under the receiver operating characteristic curve [AUC] of RDT = 0.73 [95% CI = 0.68 to 0.79] vs. AUC of ELISA = 0.70 [95% CI = 0.63 to 0.76]; p = 0.12) or as part of a published multivariable prediction model (AUC of RDT-based model = 0.74 [95% CI = 0.66 to 0.83] vs. AUC of ELISA-based model = 0.72 [95% CI = 0.64 to 0.81]; p = 0.78). Lack of agreement between the RDT and ELISA in our cohort warrants further investigation and highlights the importance of assessing candidate point-of-care tests to ensure management algorithms reflect the assay that will ultimately be used to inform patient care. Availability of a quantitative point-of-care test for suPAR opens the door to suPAR-guided risk stratification of patients with Covid-19 and other acute infections in settings with limited laboratory capacity.
Databáze: Directory of Open Access Journals