Accidental placement of central venous catheter in lung parenchyma causing hydrothorax

Autor: Vivek Badada, Tapas Kumar Singh, Uma Srivastava
Jazyk: angličtina
Rok vydání: 2014
Předmět:
Zdroj: Saudi Journal of Anaesthesia, Vol 8, Iss 5, Pp 113-114 (2014)
Druh dokumentu: article
ISSN: 1658-354X
DOI: 10.4103/1658-354X.144090
Popis: Central venous catheterization is associated with its share of complications. Most of these complications can be avoided and treated by appropriate patient selection, careful insertion technique and vigilance following catheter insertion. We report a patient presenting with unilateral hydrothorax due malposition of central venous catheter in lung parenchyma. Prompt recognition of complication and its treatment remedied the situation.