Popis: Inductively coupled plasma system was used in drinking water treatment system to kill the microorganisms in water such as total coliforms (TC), fecal coliforms (FC) and other coliforms (OC) from river water. The aim of this study was to investigate the effect of flowrate on removal efficiency (RE), death rate, and death yield and energy consumption of bacteria's. The frequency of the system was set at 4.6 MHz. The results show that the removal efficiencies and death rate of TC, FC and OC decreased with increasing flowrate. Compared to FC, the first-order reactions of TC and OC were lower in the following order: FC > OC > TC. The death yield of TC and OC significantly increased when the removal efficiency increased. The electromagnetic flux varied from 19.44 to 20.55 W/cm2 and the energy consumption was 0.26, 0.32, and 0.67 with flow rate at 20, 10 and 5 mL/minute, respectively. These results are very necessary to improve drinking water treatment.