The Global End-Diastolic Volume (GEDV) Could Be More Appropiate to Fluid Management Than Central Venous Pressure (CVP) During Closed Hyperthermic Intrabdominal Chemotherapy with CO2 Circulation

Autor: Francisco Javier Redondo, David Padilla, Pedro Villarejo, Victor Baladron, Patricia Faba, Sergio Sánchez, José Ramón Muñoz-Rodríguez, Natalia Bejarano
Jazyk: angličtina
Rok vydání: 2018
Předmět:
Zdroj: Journal of Investigative Surgery, Vol 31, Iss 4, Pp 321-327 (2018)
Druh dokumentu: article
ISSN: 0894-1939
1521-0553
08941939
DOI: 10.1080/08941939.2017.1325543
Popis: Background: Closed hyperthermic intraperitoneal chemotherapy (HIPEC) may increase abdominal pressure and effects of hemodynamic changes due to maintenance hyperthermia. Our aim was to analyze the safety and effectiveness of our closed technique with CO2 circulation in management fluid status and hemodynamic parameters by means of cardiac preload control measured by Global End Diastolic Values (GEDV) and a gas exchanger. Material and Methods: A Pilot Clinical Study that included 18 advanced ovarian cancer patients undergoing citoreductive surgery and HIPEC. We used a closed-perfusion system (PRS Combat®) that includes CO2 circulation and a gas exchanger. Transpulmonary thermodilutions and hemodynamic measurements (PiCCO2®) were performed after citoreductive surgery (Pre-HIPEC); At half time of the HIPEC (Intra-HIPEC); After HIPEC (Post-HIPEC). Results: No significant hemodynamic measurements changes in the three thermodilutions values of Cardiac Index (CI) (p = 0.227), Global End Diastolic Values (GEVD) (p = 0.966), Stroke Volume Variation (SVV) (p = 0,884) and Systemic Vascular Resistance Index (SVRI) (p = 0.082). No correlation between central venous pressure (CVP) and GEDV (Pre-HIPEC: r = 0.164, p = 0.211; Intra-HIPEC: r = 0.015, p = 0.900; Post-HIPEC: r = 0.018, p = 0.890). There was better correlation between GEDV and CI (Pre-HIPEC: r = 0.432, p = 0.071; Intra-HIPEC: r = 0.418, p = 0.074; Post-HIPEC: r = 0.411, p = 0.080). Conclusions: Closed intrabdominal chemotherapy with CO2 circulation model may be a safe model for HIPEC by means of a gas exchanger. GEDV and its changes significantly correlated to CI, and not observed for CVP. GEDV values may be more appropriate for monitoring cardiac preload, blood loss limitation and to predict changes in intravascular volume status during intraperitoneal chemotherapy.
Databáze: Directory of Open Access Journals
Nepřihlášeným uživatelům se plný text nezobrazuje