IMPACT OF PROPER METERED DOSE INHALER TECHNIQUE OVER PEAK EXPIRATORY FLOW RATE IN MODERATE PERSISTENT BRONCHIAL ASTHMA

Autor: Muhammad Hammad Athar, Usama Bin Zubair, Barik Hassan Ahmed
Jazyk: angličtina
Rok vydání: 2018
Předmět:
Zdroj: Pakistan Armed Forces Medical Journal, Vol 68, Iss 4, Pp 969-974 (2018)
Druh dokumentu: article
ISSN: 0030-9648
2411-8842
Popis: Objective: To determine the impact of proper metered dose inhaler technique over peak expiratory flow rate (PEFR) among the patients of moderate persistent bronchial asthma. Study Design: Randomized controlled trial. Place and Duration of Study: Military Hospital Rawalpindi, Six months, from Dec 2017 to Jun 2018. Material and Methods: The sample population comprised of patients suffering from moderate persistent bronchial asthma presenting in medical outpatient department. Patients were divided into two groups. Patients in group A were not educated regarding proper technique for using metered dose inhaler and used the faulty technique. Patients in group B were educated regarding proper technique for using metered dose inhaler. Peak expiratory flow rate was determined via standard peak expiratory flow rate device in both the groups after the inhalation of standard dose of salbutamol. Mean PEFR was calculated and compared for both the groups. Results: The mean peak expiratory flow rate score of patients without the education of proper technique was 320 ± 9.28 whereas mean PEFR score in patients after the proper metered dose inhaler technique was 460 ± 6.66 (p-value
Databáze: Directory of Open Access Journals