Electromedical Device And Expert System for Early Detection of Hyperemesis Gravidarum

Autor: Fitrilina Fitrilina, Ganesha, Yanolanda Suzantry Handayani, Alex Surapati, Rahayu Trisetyowati Untari, Heru Dibyo Laksono, Melda Latif
Jazyk: English<br />Indonesian
Rok vydání: 2023
Předmět:
Zdroj: Jurnal Nasional Teknik Elektro, Pp 30-36 (2023)
Druh dokumentu: article
ISSN: 2302-2949
2407-7267
DOI: 10.25077/jnte.v12n3.1130.2023
Popis: Hyperemesis Gravidarum (HG) is a pregnancy complication that is often overlooked as it is typically considered normal. If HG is not properly treated, nutrition will not be fulfilled which can negatively affect maternal and fetal health and even maternal and fetal death. The exact cause of HG is not identified, so there are no effective preventive methods. However early detection can help for prompt and appropriate treatment. Therefore, a monitoring system for pregnancy conditions was designed for HG early detection. This system employs the MPX5050 DP pressure sensor for measuring blood pressure, the MAX30100 for assessing maternal heart rate and oxygen saturation, the MAX4466 sensor for monitoring fetal heart rate, and an expert system using the certainty factor method to diagnose the probability of hyperemesis gravidarum. The expert system achieves an accuracy of 93.33%. In comparison to the aneroid sphygmomanometer, the designed sphygmomanometer reveals a mean difference of 3.5 mmHg for diastolic pressure, with a standard deviation below 8 mmHg for both systolic and diastolic pressures. The measurement of heart rate and oxygen saturation has a deviation of 1.8 % and 1.02 % respectively. These deviations align with the standards specified by the Ministry of Health for medical devices. For the fetal heart rate, the mean deviation is 3.4 bpm, and the measurement error is 2.38%. Thus, this system can be utilized to monitor pregnancy conditions, enabling the early detection of hyperemesis gravidarum
Databáze: Directory of Open Access Journals