Validation of an automated contouring and treatment planning tool for pediatric craniospinal radiation therapy

Autor: Soleil Hernandez, Hester Burger, Callistus Nguyen, Arnold C. Paulino, John T. Lucas, Austin M. Faught, Jack Duryea, Tucker Netherton, Dong Joo Rhee, Carlos Cardenas, Rebecca Howell, David Fuentes, Julianne Pollard-Larkin, Laurence Court, Jeannette Parkes
Jazyk: angličtina
Rok vydání: 2023
Předmět:
Zdroj: Frontiers in Oncology, Vol 13 (2023)
Druh dokumentu: article
ISSN: 2234-943X
DOI: 10.3389/fonc.2023.1221792
Popis: PurposeTreatment planning for craniospinal irradiation (CSI) is complex and time-consuming, especially for resource-constrained centers. To alleviate demanding workflows, we successfully automated the pediatric CSI planning pipeline in previous work. In this work, we validated our CSI autosegmentation and autoplanning tool on a large dataset from St. Jude Children’s Research Hospital.MethodsSixty-three CSI patient CT scans were involved in the study. Pre-planning scripts were used to automatically verify anatomical compatibility with the autoplanning tool. The autoplanning pipeline generated 15 contours and a composite CSI treatment plan for each of the compatible test patients (n=51). Plan quality was evaluated quantitatively with target coverage and dose to normal tissue metrics and qualitatively with physician review, using a 5-point Likert scale. Three pediatric radiation oncologists from 3 institutions reviewed and scored 15 contours and a corresponding composite CSI plan for the final 51 test patients. One patient was scored by 3 physicians, resulting in 53 plans scored total.ResultsThe algorithm automatically detected 12 incompatible patients due to insufficient junction spacing or head tilt and removed them from the study. Of the 795 autosegmented contours reviewed, 97% were scored as clinically acceptable, with 92% requiring no edits. Of the 53 plans scored, all 51 brain dose distributions were scored as clinically acceptable. For the spine dose distributions, 92%, 100%, and 68% of single, extended, and multiple-field cases, respectively, were scored as clinically acceptable. In all cases (major or minor edits), the physicians noted that they would rather edit the autoplan than create a new plan.ConclusionsWe successfully validated an autoplanning pipeline on 51 patients from another institution, indicating that our algorithm is robust in its adjustment to differing patient populations. We automatically generated 15 contours and a comprehensive CSI treatment plan for each patient without physician intervention, indicating the potential for increased treatment planning efficiency and global access to high-quality radiation therapy.
Databáze: Directory of Open Access Journals