Autor: |
S. Rajesh, Venkatesh Kasi Arunachalam, Gopinath Periaswamy, Gobi Kalyan, Rupa Renganathan, Gowtham SM, Mathew Cherian |
Jazyk: |
angličtina |
Rok vydání: |
2023 |
Předmět: |
|
Zdroj: |
Journal of Gastrointestinal and Abdominal Radiology, Vol 06, Iss 02, Pp 079-088 (2023) |
Druh dokumentu: |
article |
ISSN: |
2581-9178 |
DOI: |
10.1055/s-0043-1763483 |
Popis: |
Background and Objectives The purpose of this study is to evaluate and establish the accuracy of noninvasive methods, including third-generation dual-source dual-energy computed tomography (DECT) and proton density fat (PDF) fraction on magnetic resonance imaging (MRI) using three-dimensional multiecho multipoint chemical shift-encoded spoiled gradient echo (q-Dixon) sequence in the quantification of hepatic steatosis; with H1-MR spectroscopy (MRS) as the reference standard. Materials and Methods A total of 47 patients were included in this prospective study. We studied the accuracy of fatty liver detection using third-generation DECT using mixed set images (MSIs), virtual monochromatic images (VMIs), and MRI q-Dixon. The results were compared with H1-MRS. Data were analyzed using linear regression for each technique compared with MRS. Results Our study's correlation and linear regression analysis showed a good correlation between PDF values obtained by H1-MRS and MR q-Dixon methods (r = 0.821, r 2 = 0.674, p |