Contrast enhanced transesophageal echocardiography in patients with atrial fibrillation referred to electrical cardioversion improves atrial thrombus detection and may reduce associated thromboembolic events

Autor: Jung Philip H, Mueller Marisa, Schuhmann Christoph, Eickhoff Madeleine, Schneider Philip, Seemueller Gueler, Dutton Raphael, Rieber Johannes, Kääb Stefan, Sohn Hae-Young
Jazyk: angličtina
Rok vydání: 2013
Předmět:
Zdroj: Cardiovascular Ultrasound, Vol 11, Iss 1, p 1 (2013)
Druh dokumentu: article
ISSN: 1476-7120
DOI: 10.1186/1476-7120-11-1
Popis: Abstract Aims Transesophageal echocardiography (TEE) is the gold standard for the detection of thrombi in patients with atrial fibrillation (AF) before undergoing early electrical cardioversion (CV). However, TEE generates inconclusive results in a considerable number of patients. This study investigated the influence of contrast enhancement on interpretability of TEE for the detection of left atrial (LA) thrombi compared to conventional TEE and assessed, whether there are differences in the rate of thromboembolic events after electrical cardioversion. Methods Of 180 patients with AF (51 females, 65.2±13 years) who were referred to CV, 90 were examined with native imaging and contrast enhancement within the same examination (group 1), and 90 were examined with native TEE alone and served as control (group 2). Cineloops of the multiplane examination of the LA and LA appendage (LAA) were stored digitally before and, in group 1, after intravenous bolus application of a transpulmonary contrast agent. Images of group 1 were assessed offline and the diagnosis of LA thrombi was made semi-quantitatively: 1= thrombus present; 2=inconclusive result; 3=no thrombus. The presence of spontaneous echocontrast (SEC) was registered and flow velocity in the LA appendage (LAA-flow) was measured. All patients in whom CV was performed were followed up for 1 year or until relapse of AF. CV related adverse events were defined as any thromboembolic event within 1 week after CV. Results No serious adverse events occurred during TEE and contrast enhanced imaging. In group 1 atrial thrombi were diagnosed in 14 (15.6%) during native and in 10 (11.1%) patients during contrast enhanced imaging (p Conclusion In patients with AF planned for CV contrast enhancement renders TEE images more interpretable, facilitates the exclusion of atrial thrombi and may reduce the rate of embolic adverse events.
Databáze: Directory of Open Access Journals