Shear Bond Strength of Molar Tubes to Enamel Using an Orthodontic Resin-Modified Glass Ionomer Cement Modified with Amorphous Calcium Phosphate

Autor: Behrad Tanbakuchi, Tabassom Hooshmand, Mohammad Javad Kharazifard, Kiana Shekofteh, Arian Hesam Arefi
Jazyk: angličtina
Rok vydání: 2020
Předmět:
Zdroj: Frontiers in Dentistry, Pp 369-378 (2020)
Druh dokumentu: article
ISSN: 2676-296X
DOI: 10.18502/fid.v16i5.2286
Popis: Objectives: This study aimed to assess the shear bond strength (SBS) of molar tubes to the enamel surface of molar teeth using a resin-modified glass ionomer (RMGI) cement modified with amorphous calcium phosphate (ACP). Materials and Methods: In this in-vitro study, 60 extracted human third molars were randomly divided into four groups for bonding of molar tubes to the enamel surface. Fuji Ortho LC and Fuji Ortho LC modified with ACP (1.55 wt%) were used in groups 1 and 2, respectively. In group 3, the enamel surface was sandblasted, and bonding was then performed using Fuji Ortho LC glass ionomer modified with ACP. In group 4, molar tubes were conventionally bonded using Transbond XT composite. The SBS was measured using a universal testing machine. Results: The mean SBS of groups 1 to 4 was 10.22, 6.88, 9.4, and 13.68 MPa, respectively. Only the SBS of group 1 was not significantly different from that of groups 3 and 4 (P>0.05). Comparison of adhesive remnant index (ARI) scores of the groups revealed significant differences only between groups 1 and 4 (P
Databáze: Directory of Open Access Journals