Autor: |
Maria P Bambo, Beatriz Cameo, Ruben Hernandez, Enrique Fuentemilla, Noemi Güerri, Blanca Ferrandez, Vicente Polo, Jose M Larrosa, Luis E Pablo, Elena Garcia-Martin |
Jazyk: |
angličtina |
Rok vydání: |
2018 |
Předmět: |
|
Zdroj: |
PLoS ONE, Vol 13, Iss 6, p e0198397 (2018) |
Druh dokumentu: |
article |
ISSN: |
1932-6203 |
DOI: |
10.1371/journal.pone.0198397 |
Popis: |
PURPOSE:To evaluate the diagnostic ability of macular ganglion cell (mGCL) and macular retinal nerve fiber (mRNFL) layers, to detect early glaucomatous eyes, using the new segmentation software of Spectralis optical coherence tomography (OCT) device (Heidelberg Engineering). METHODS:A total of 83 eyes from 83 subjects were included in this observational, prospective cross-sectional study: 43 healthy controls and 40 early primary open-angle glaucoma (POAG) patients. All participants were examined using the Horizontal and Vertical Posterior Pole protocols, and the peripapillary RNFL (pRNFL) protocol of Spectralis OCT device. The new automated retinal segmentation software was applied to horizontal and vertical macular B-scans to determine mGCL and mRNFL thicknesses in each one of the 9 sectors of the Early Treatment Diagnostic Retinopathy Study circle. Thickness of each layer was compared between groups, and the sectors with better area under the receiver operating characteristic curve (AUC) were identified. RESULTS:mGCL was significantly thinner in the POAG group, especially in outer and inner temporal sectors (p |
Databáze: |
Directory of Open Access Journals |
Externí odkaz: |
|
Nepřihlášeným uživatelům se plný text nezobrazuje |
K zobrazení výsledku je třeba se přihlásit.
|