Autor: |
Simona Manole, Claudia Budurea, Sorin Pop, Alin M. Iliescu, Cristiana A. Ciortea, Stefania D. Iancu, Loredana Popa, Mihaela Coman, László Szabó, Vasile Coman, Zoltán Bálint |
Jazyk: |
angličtina |
Rok vydání: |
2021 |
Předmět: |
|
Zdroj: |
Life, Vol 11, Iss 12, p 1362 (2021) |
Druh dokumentu: |
article |
ISSN: |
2075-1729 |
DOI: |
10.3390/life11121362 |
Popis: |
Aims: We aimed to compare cardiac volumes measured with echocardiography (echo) and cardiac magnetic resonance imaging (MRI) in a mixed cohort of healthy controls (controls) and patients with atrial fibrillation (AF). Materials and methods: In total, 123 subjects were included in our study; 99 full datasets were analyzed. All the participants underwent clinical evaluation, EKG, echo, and cardiac MRI acquisition. Participants with full clinical data were grouped into 63 AF patients and 36 controls for calculation of left atrial volume (LA Vol) and 51 AF patients and 30 controls for calculation of left ventricular end-diastolic volume (LV EDV), end-systolic volume (ESV), and LV ejection fraction (LV EF). Results: No significant differences in LA Vol were observed (p > 0.05) when measured by either echo or MRI. However, echo provided significantly lower values for left ventricular volume (p < 0.0001). The echo LA Vol of all the subjects correlated well with that measured by MRI (Spearmen correlation coefficient r = 0.83, p < 0.0001). When comparing the two methods, significant positive correlations of EDV (all subjects: r = 0.55; Controls: r = 0.71; and AF patients: r = 0.51) and ESV (all subjects: r = 0.62; Controls: r = 0.47; and AF patients: r = 0.66) were found, with a negative bias for values determined using echo. For a subgroup of participants with ventricular volumes smaller than 49.50 mL, this bias was missing, thus in this case echocardiography could be used as an alternative for MRI. Conclusion: Good correlation and reduced bias were observed for LA Vol and EF determined by echo as compared to cardiac MRI in a mixed cohort of patients with AF and healthy volunteers. For the determination of volume values below 49.50 mL, an excellent correlation was observed between values obtained using echo and MRI, with comparatively reduced bias for the volumes determined by echo. Therefore, in certain cases, echocardiography could be used as a less expensive, less time-consuming, and contraindication free alternative to MRI for cardiac volume determination. |
Databáze: |
Directory of Open Access Journals |
Externí odkaz: |
|
Nepřihlášeným uživatelům se plný text nezobrazuje |
K zobrazení výsledku je třeba se přihlásit.
|