Autor: |
Barbara Roqueto dos Reis, Ryan K. Wright, Riley Thompson, Nikki Tabatabai, Katherine Amirault, Sathya Sujani, Robin R. White |
Jazyk: |
angličtina |
Rok vydání: |
2024 |
Předmět: |
|
Zdroj: |
Frontiers in Veterinary Science, Vol 11 (2024) |
Druh dokumentu: |
article |
ISSN: |
2297-1769 |
DOI: |
10.3389/fvets.2024.1458044 |
Popis: |
This study evaluated the feasibility of utilizing a continuous glucose monitors (CGM) designed for use in humans to measure glucose levels in sheep. Four Suffolk x Dorset sheep were fitted with jugular catheters and FreeStyle Libre 2 (Abbott®) glucose monitors. Glucose concentration from the CGM were compared with those from a glucometer and traditional assays during a hyperglycemic clamp, aiming to explore a broader range of physiological glucose concentrations in a controlled manner. Measurements were taken every five minutes during the infusion and every ten minutes post-infusion until baseline levels were restored. Relationships were analyzed using a linear mixed-effects model with glucometer readings as the response variables, GCM reading as fixed effects, and animal as random effect with significant level of p |
Databáze: |
Directory of Open Access Journals |
Externí odkaz: |
|