Structure-specific rigid dose accumulation dosimetric analysis of ablative stereotactic MRI-guided adaptive radiation therapy in ultracentral lung lesions

Autor: J. M. Bryant, Ruben J. Cruz-Chamorro, Alberic Gan, Casey Liveringhouse, Joseph Weygand, Ann Nguyen, Emily Keit, Maria L. Sandoval, Austin J. Sim, Bradford A. Perez, Thomas J. Dilling, Gage Redler, Jacqueline Andreozzi, Louis Nardella, Arash O. Naghavi, Vladimir Feygelman, Kujtim Latifi, Stephen A. Rosenberg
Jazyk: angličtina
Rok vydání: 2024
Předmět:
Zdroj: Communications Medicine, Vol 4, Iss 1, Pp 1-10 (2024)
Druh dokumentu: article
ISSN: 2730-664X
DOI: 10.1038/s43856-024-00526-7
Popis: Abstract Background Definitive local therapy with stereotactic ablative radiation therapy (SABR) for ultracentral lung lesions is associated with a high risk of toxicity, including treatment related death. Stereotactic MR-guided adaptive radiation therapy (SMART) can overcome many of the challenges associated with SABR treatment of ultracentral lesions. Methods We retrospectively identified 14 consecutive patients who received SMART to ultracentral lung lesions from 10/2019 to 01/2021. Patients had a median distance from the proximal bronchial tree (PBT) of 0.38 cm. Tumors were most often lung primary (64.3%) and HILUS group A (85.7%). A structure-specific rigid registration approach was used for cumulative dose analysis. Kaplan-Meier log-rank analysis was used for clinical outcome data and the Wilcoxon Signed Rank test was used for dosimetric data. Results Here we show that SMART dosimetric improvements in favor of delivered plans over predicted non-adapted plans for PBT, with improvements in proximal bronchial tree DMax of 5.7 Gy (p = 0.002) and gross tumor 100% prescription coverage of 7.3% (p = 0.002). The mean estimated follow-up is 17.2 months and 2-year local control and local failure free survival rates are 92.9% and 85.7%, respectively. There are no grade ≥ 3 toxicities. Conclusions SMART has dosimetric advantages and excellent clinical outcomes for ultracentral lung tumors. Daily plan adaptation reliably improves target coverage while simultaneously reducing doses to the proximal airways. These results further characterize the therapeutic window improvements for SMART. Structure-specific rigid dose accumulation dosimetric analysis provides insights that elucidate the dosimetric advantages of SMART more so than per fractional analysis alone.
Databáze: Directory of Open Access Journals