The aim of the present study was to determine if an inertial measurement unit placed on the metatarsal part of the foot can provide valid and reliable data for an accurate estimate of vertical jump height. Thirteen female volleyball players participated in the study. All players were members of the Republic of Serbia national team. Measurement of the vertical jump height was performed for the two exemplary jumping tasks, squat jump and counter-movement jump. Vertical jump height estimation was performed using the flight time method for both devices. The presented results support a high level of concurrent validity of an inertial measurement unit in relation to a force plate for estimating vertical jump height (CMJ t = 0.897, p = 379; ICC = 0.975; SQJ t = −0.564, p = 0.578; ICC = 0.921) as well as a high level of reliability (ICC > 0.872) for inertial measurement unit results. The proposed inertial measurement unit positioning may provide an accurate vertical jump height estimate for in-field measurement of jump height as an alternative to other devices. The principal advantages include the small size of the sensor unit and possible simultaneous monitoring of multiple athletes. |