Treatment of extremity fractures in dogs using external fixators with closed reduction and limited open approach

Autor: S. Özsoy, K. Altunatmaz
Jazyk: angličtina
Rok vydání: 2003
Předmět:
Zdroj: Veterinární Medicína, Vol 48, Iss 5, Pp 133-140 (2003)
Druh dokumentu: article
ISSN: 0375-8427
1805-9392
DOI: 10.17221/5760-VETMED
Popis: Humerus, tibia and antebrachium fractures determined in 30 dogs of different breed, age, weight and gender were treated using Type I and II external fixators. Meynard and handcuff clamps were used in the external fixators. Limited open approach was applied in 6 of the cases and closed reduction techniques in 24. In cases where closed reduction and stabilisation was done, the patients were seen to use their leg within 3-10 days post-operatively and that walking was reasonably good after 20 days. In cases to which a limited open approach had been applied, use of leg was achieved in a period close to the closed method.