The semi-compliant balloon bounce technique for total femoral approach during fenestrated-branched endovascular aortic aneurysm repair

Autor: Guilherme B. Lima, MD, PhD, Nolan C. Cirillo-Penn, MD, Jesse Chait, DO, Randal R. DeMartino, MD, MS, Bernardo C. Mendes, MD
Jazyk: angličtina
Rok vydání: 2024
Předmět:
Zdroj: Journal of Vascular Surgery Cases and Innovative Techniques, Vol 10, Iss 3, Pp 101429- (2024)
Druh dokumentu: article
ISSN: 2468-4287
DOI: 10.1016/j.jvscit.2024.101429
Popis: A total femoral approach for fenestrated-branched endovascular aortic aneurysm repair has been increasingly favored to minimize risks of aortic arch manipulation. We describe a novel technique to support the advancement of endovascular devices into a target vessel. Following catheterization of the intended target artery and deployment of the diameter-reducing ties, a Coda semi-compliant balloon (Cook Medical) is advanced and inflated immediately above the target artery. It is used as a support as the wire, catheter, or sheath “bounces” on the balloon, stabilizing the support wire to advance stent grafts, balloons, or sheaths into the downward renal or mesenteric vessels.