Popis: |
Abstract Preprocedural ultrasound assistance can enhance the efficacy of neuraxial anesthesia in obstetrics. We investigated whether the use of handheld ultrasound can shorten the procedural time of labor combined spinal-epidural (CSE) analgesia compared with conventional landmark-guided methods. Eighty-four women requesting labor analgesia were randomly assigned to either handheld ultrasound-assisted or palpation-guided CSE analgesia. Primary outcome was procedure time of the CSE analgesia. Secondary outcomes included identification time, performance time, number of needle manipulations required for epidural/spinal success, first-attempt success rate, periprocedural pain scores, the incidence of accidental dural puncture, and patient satisfaction. Total procedure time did not significantly differ between the ultrasound and palpation groups (median [IQR], 191.5 [167–224] vs. 204.5 [163–358] s; P = 0.442). However, the performance time was significantly shorter in the ultrasound group (134.5 [115–177] vs. 183 [129–296] s; P = 0.011), although identification time was longer in the ultrasound group (53 [41–72] vs. 30.5 [21–45] s; P |