Experimental setup to fabricate Rb–Xe gas cells for atom spin gyroscopes

Autor: S. H. Yim, D.-Y. Lee, S. Lee, M. M. Kim
Jazyk: angličtina
Rok vydání: 2022
Předmět:
Zdroj: AIP Advances, Vol 12, Iss 1, Pp 015025-015025-9 (2022)
Druh dokumentu: article
ISSN: 2158-3226
DOI: 10.1063/5.0069211
Popis: An experimental setup to fabricate atomic vapor cells for atom spin gyroscope application, containing 87Rb, 129Xe, 131Xe, N2, and H2, is described. The setup comprises a high-vacuum chamber, an 87Rb ampule, a glass cell, gas lines, and a turbopump. First, the glass cell is baked for a week at 450 °C to reduce outgassing from the inner walls of the glass cell. Next, rubidium atoms are evaporated into the cubic glass cell. Then, the cubic glass cell is cooled to 2 °C to increase the amount of 87Rb in the cubic glass cell while the vacuum chamber is heated to 100 °C. 6 Torr of 129Xe, 48 Torr of 131Xe, 140 Torr of N2, and 24 Torr of H2 are injected into the cubic glass cell. The sealing method employs pinch-off glass welding. The transverse spin relaxation times of 129Xe and 131Xe at a magnetic field of 6.2 µT applied to the quantization axis are measured to be 8.1 and 16.5 s, respectively, at a cell temperature of 96 °C using nuclear magnetic resonance spectroscopy. The pressure ratio between 129Xe and 131Xe is determined by comparing the output signals from our atom spin gyroscope. The signal-to-noise ratios are 2500 for 129Xe and 3333 for 131Xe, respectively, and the expected angular random walk of the atom spin gyroscope is 0.062°/h1/2 with a 1-Hz repetition rate.
Databáze: Directory of Open Access Journals