Three-dimensional misfit between Ti-Base abutments and implants evaluated by replica technique
Autor: | Karina Bergamo Cardoso, Edmara Tatiely Pedroso Bergamo, Vitor De Moraes Cruz, Ilana Santos Ramalho, Lucas Fracassi De Oliveira Lino, Estevam Augusto Bonfante |
---|---|
Jazyk: | angličtina |
Předmět: | |
Zdroj: | Journal of Applied Oral Science |
Druh dokumentu: | article |
ISSN: | 1678-7765 1678-7757 |
DOI: | 10.1590/1678-7757-2020-0343 |
Popis: | Abstract An important factor affecting the biomechanical behavior of implant-supported reconstructions is the implant-abutment misfit. Objective: This study evaluated the misfit between Ti-Base abutments and implants by means of polyvinyl siloxane replica technique using microcomputed tomography (μCT). Methodology: Volumetric and linear (central and marginal) gaps of four Ti-base abutments (n=10/group): (i) Odontofix LTDA (OD), (ii) Singular Implants (SING), (iii) EFF Dental Components (EFF), and (iv) Control Group (S.I.N implants) compatible with an implant system (Strong SW, S.I.N Implants) were measured using μCT reconstructed polyvinyl siloxane replicas. Results: The results showed significantly lower volume gap for Control S.I.N (0.67±0.29 mm3) and SING (0.69±0.28 mm3) Ti-base abutments relative to OD (1.42±0.28 mm3) and EFF groups (1.04±0.28 mm3) (p |
Databáze: | Directory of Open Access Journals |
Externí odkaz: |