Diagnostic accuracy of computer-aided detection of pulmonary tuberculosis in chest radiographs: a validation study from sub-Saharan Africa.

Autor: Marianne Breuninger, Bram van Ginneken, Rick H H M Philipsen, Francis Mhimbira, Jerry J Hella, Fred Lwilla, Jan van den Hombergh, Amanda Ross, Levan Jugheli, Dirk Wagner, Klaus Reither
Jazyk: angličtina
Rok vydání: 2014
Předmět:
Zdroj: PLoS ONE, Vol 9, Iss 9, p e106381 (2014)
Druh dokumentu: article
ISSN: 1932-6203
DOI: 10.1371/journal.pone.0106381
Popis: Chest radiography to diagnose and screen for pulmonary tuberculosis has limitations, especially due to inter-reader variability. Automating the interpretation has the potential to overcome this drawback and to deliver objective and reproducible results. The CAD4TB software is a computer-aided detection system that has shown promising preliminary findings. Evaluation studies in different settings are needed to assess diagnostic accuracy and practicability of use.CAD4TB was evaluated on chest radiographs of patients with symptoms suggestive of pulmonary tuberculosis enrolled in two cohort studies in Tanzania. All patients were characterized by sputum smear microscopy and culture including subsequent antigen or molecular confirmation of Mycobacterium tuberculosis (M.tb) to determine the reference standard. Chest radiographs were read by the software and two human readers, one expert reader and one clinical officer. The sensitivity and specificity of CAD4TB was depicted using receiver operating characteristic (ROC) curves, the area under the curve calculated and the performance of the software compared to the results of human readers.Of 861 study participants, 194 (23%) were culture-positive for M.tb. The area under the ROC curve of CAD4TB for the detection of culture-positive pulmonary tuberculosis was 0.84 (95% CI 0.80-0.88). CAD4TB was significantly more accurate for the discrimination of smear-positive cases against non TB patients than for smear-negative cases (p-value
Databáze: Directory of Open Access Journals