In vivo assessment of safety, biodistribution, and radiation dosimetry of the [18F]Me4FDG PET-radiotracer in adults

Autor: Barbara Katharina Geist, Juan Carlos Ramirez, Patrick Binder, Holger Einspieler, Harald Ibeschitz, Werner Langsteger, Lukas Nics, Ivo Rausch, Markus Diemling, Antti Sohlberg, Marcus Hacker, Sazan Rasul
Jazyk: angličtina
Rok vydání: 2024
Předmět:
Zdroj: EJNMMI Research, Vol 14, Iss 1, Pp 1-7 (2024)
Druh dokumentu: article
ISSN: 2191-219X
DOI: 10.1186/s13550-024-01098-2
Popis: Abstract Background Approaches targeting the sodium-glucose cotransporter (SGLT) could represent a promising future therapeutic strategy for numerous oncological and metabolic diseases. In this study, we evaluated the safety, biodistribution and radiation dosimetry of the glucose analogue positron emission tomography (PET) agent [18F] labeled alpha-methyl-4-deoxy-4-[18F]fluoro-D-glucopyranoside ([18F]Me4FDG) with high sodium-glucose cotransporter and low glucose transporter (GLUT) affinity. For this purpose, five healthy volunteers (1 man, 4 women) underwent multiple whole-body PET/computed tomography (CT) examinations starting with injection and up to 4 h after injection of averaged (2.4 ± 0.1) MBq/kg (range: 2.3–2.5 MBq/kg) administered activity. The PET/CT scans were conducted in 5 separate sessions, blood pressure and temperature were measured, and blood and urine samples were collected before the scans and one hour after injection to assess toxicity. Measurements of [18F]Me4FDG radioactivity in organs of interest were determined from the PET/CT scans at 5 time points. Internal dosimetry was performed on voxel level using a fast Monte Carlo approach. Results All studied volunteers could well tolerate the [18F]Me4FDG and no adverse event was reported. The calculated effective dose was (0.013 ± 0.003) mSv/MBq. The organs with the highest absorbed dose were the kidneys with 0.05 mSv/MBq per kidney. The brain showed almost no uptake. After 60 min, (12 ± 15) % of the administered dose was excreted into the bladder. Conclusion Featuring an effective dose of only 0.013 ± 0.003 mSv/MBq and no occurrence of side effects, the glucose analogue [18F]Me4FDG seems to be a safe radio-tracer with a favorable biodistribution for PET imaging and also within several consecutive scans. Trial registration number NCT03557138, Registered 22 February 2017, https://ichgcp.net/clinical-trials-registry/NCT03557138 .
Databáze: Directory of Open Access Journals
Nepřihlášeným uživatelům se plný text nezobrazuje